pisco_log
banner

Determination of Air Leakage of Auxiliary Ventilation Ducting Sys- tem in VANG DANH Underground Mine

Phuongthao Dang, Vanduyen Bui

Abstract


Air leakage of air movement through the ducting system in underground mine is an important factor in ensuring the
efficiency of ventilation during mining roadways being driven in mine. This value plays an important role in the reasonable design
of auxiliary ventilation as well as in the energy cost in the mine.
Experimental data of the duct air leakage are made on 0.8 m diameter ducts over sections of ducts installing towards the working
face in Vang Danh mine. Determination of the air leakage in ducting system have been undertaken.

Keywords


Air leakage; Auxiliary ventilation; Duct; Working face; Ventilation efficiency; Operating costs

Full Text:

PDF

Included Database


References


["[1] Onder, M., Sarac, S. and Cevik, E., The influence of ventilation variables on the volume rate of airflow delivered to the face of long drivages. Tunneling and Underground Space Technology, 21(5), pp. 568-574, (2006)","[2] T.Stefanov, E. Vlasseva, Untight pipeline ventilation systemsu2019calculations, 50 years University of Mining and Geology u201cSt. Ivan Rilskiu201d Annual, Vol. 46, part u0406I, Mining and Mineral Processing, Sofia, pu0440.155-162, (2003)."]




DOI: https://doi.org/10.18282/l-e.v10i6.2857

Refbacks

  • There are currently no refbacks.